            當前位置 >首頁 >成功案例 >冶金 > 河鋼石鋼軋鋼廠大棒線風機測試報告
            河鋼石鋼軋鋼廠大棒線風機測試報告
            作者:龍城國際  時間:2020-03-23 17:03:07  點擊率:4904
            高溫引風機測試數據
            高溫引風機測試數據,風機前端軸承座振動2.5mm/s,后端振動2.68mm/s,在規定范圍內。
            0號風機時域波形
            0號風機時域波形
            0號風機頻域波形
            0號風機頻域波形
            因此風機,長時間沒有進行運轉,需要定檢檢查。0號風機振動值超標,風機前軸承座振動18.14mm/s,后軸承座14.21mm/s根據圖譜可以看出1/2倍頻占主導頻率,3倍頻,4倍頻也有伴隨頻率出現,說明軸承有松動現象,可能是軸承間隙、油隙出現問題,建議停機檢查,再進行動平衡校正。


            3號風機頻域圖
            3號風機頻域圖
            3號風機時域波形
            3號風機時域波形
            3號風機振動在規定范圍內,振動良好。

            4號風機時域圖
            4號風機時域圖
            4號風機頻域圖
            4號風機頻域圖
            4號風機振動超標,前端軸承座振動6.20mm/s,后端軸承座振動4.44mm/s,根據圖譜可以看出雖然1倍頻25HZ振動大,但1/2倍頻卻超過1倍頻振動副值,并且2倍頻接近1倍頻副值,說明風機同心度不好,并且軸承間隙、油隙,導致風機振動大,建議停機檢查調同心度,查看軸承間隙大小。再進行動平衡校正。